Logo

NHS DTAC in 2026: What Digital Health Software Must Pass

  1. Nabeel Al Nassir

  2. November 23, 2026

  3. 9 Min read

pixbit solutions

The NHS Digital Technology Assessment Criteria, known as DTAC, is the assessment NHS and social care buyers use to check digital health software before they buy it. The supplier completes the form and the buyer assesses it. An updated version replaced the original form from 6 April 2026, with about a quarter fewer questions. It assesses five areas: clinical safety, data protection, technical security, interoperability, and usability and accessibility.

What DTAC Is and Who Uses It

DTAC is NHS England's baseline assessment for software-based digital health technologies. That covers apps, websites, platforms and other software that handles health and care data, whether it is used by clinicians, by patients or by care staff. NHS trusts, integrated care boards, GP practices and social care providers use it as part of their due diligence before buying or deploying a product, and for many NHS procurements a completed DTAC form is a threshold requirement.

The roles are clear. The manufacturer of the software completes the DTAC form and supplies the supporting evidence. The buying organisation assesses it, with professional oversight from people who understand each area, such as a clinical safety officer, an information governance lead and a technical security specialist. Where a supplier's service relies on another manufacturer's product, each product's manufacturer should provide its own completed form.

DTAC is an assessment framework, not a certificate. NHS England and the Department of Health and Social Care have been explicit that passing a DTAC assessment with one buyer is not a badge that applies everywhere, and buyers are expected to reassess elements that expire or change when the product is updated.

What Changed in the 2026 Update

NHS England reviewed DTAC in 2024, engaging with suppliers and NHS organisations, and published a refreshed form and guidance in February 2026. The previous form should not be used from 6 April 2026 onwards.

The headline change is a shorter form, with about 25 per cent fewer questions. Questions that duplicated the Data Security and Protection Toolkit, known as the DSPT, and the Pre-Acquisition Questionnaire for medical devices have been removed. The guidance now explains DTAC's purpose, scope and governance more clearly, including how it applies to pilots and to procurements involving several organisations.

The scope now aligns with the National Institute for Health and Care Excellence definition of digital health technologies. DTAC covers standalone software and software used with hardware, but not hardware itself or embedded operational software such as firmware. Where a product combines both, DTAC applies to the software, and the clinical risk documentation must still cover the whole system.

Several specific requirements changed. The requirement for the clinical safety officer to complete NHS-provided training no longer applies, although suitable training remains good practice. A decision tree now helps suppliers work out whether their product is a medical device and which clinical safety standard applies. Usability and accessibility is no longer scored and is reviewed comparatively, and it now references WCAG 2.2 at level AA. NHS England has said it will update DTAC again as the review of the DCB0129 and DCB0160 clinical safety standards concludes and as medical device rules change.

The Five Assessed Areas, Section by Section

The form opens with company information and a value proposition, which give context but are not assessed. The assessed sections follow.

Clinical safety, section C1, applies where a product provides information that influences, supports or manages direct patient care. The manufacturer must follow DCB0129, the clinical risk management standard for manufacturers of health IT. In practice that means a named clinical safety officer who is a registered clinician, a documented clinical risk management system, a hazard log that records each hazard with its causes, controls and residual risk, and a clinical safety case report signed off by the clinical safety officer. Software that qualifies as a medical device also triggers the Pre-Acquisition Questionnaire and needs registration with the MHRA.

Data protection, section C2, checks how the product handles personal data. Products that access NHS patient data or systems need a DSPT assessment at Standards Met or above, and the supplier needs to be registered with the Information Commissioner. Most digital health products need a Data Protection Impact Assessment, and the expectations now match NHS England's standard template. Suppliers must provide privacy information and their terms and conditions, document where data is stored and processed, and justify any transfer outside the UK using the appropriate mechanisms, such as the International Data Transfer Agreement with a transfer risk assessment.

Technical security, section C3, checks how the product is built and run. Suppliers must confirm they follow the Software Security Code of Practice published by the Department for Science, Innovation and Technology and the National Cyber Security Centre. Buyers commonly expect Cyber Essentials certification or a commitment under the cyber security charter for NHS suppliers, an external penetration test within the past twelve months, and multi-factor authentication for administrator and remote access accounts.

Interoperability, section C4, checks how the product exchanges data with NHS systems. Suppliers must explain which APIs and data standards they use and why, with reference to recognised NHS guidance. HL7 FHIR is the usual choice for modern NHS integrations, as covered in our guide to FHIR interoperability for UK home care software. Products that use the NHS Number must validate it properly, typically through the Personal Demographics Service, and patient-facing products are expected to consider NHS login for identity verification.

Usability and accessibility, section D, asks for evidence of user research and testing, conformance with WCAG 2.2 AA or a plan to reach it, an accessibility statement, and consideration of the Accessible Information Standard.

SectionWhat it coversTypical evidence
C1 Clinical safetyPatient safety risks in the softwareDCB0129 risk management system, hazard log, safety case, named clinical safety officer
C2 Data protectionLawful, transparent handling of personal dataDSPT, ICO registration, DPIA, privacy information, data location
C3 Technical securityHow the product is built, hosted and protectedSoftware Security Code of Practice, Cyber Essentials, penetration test, MFA
C4 InteroperabilityData exchange with NHS systemsAPI and standards rationale, NHS Number validation, NHS login where relevant
D Usability and accessibilityWhether people can use the productUser research, WCAG 2.2 AA, accessibility statement

Building Software That Passes DTAC

The cheapest time to meet DTAC is before the code is written. Retrofitting a hazard log, audit trails or accessible interfaces into a finished product is slow and expensive, and gaps found during a procurement can stall a sale for months.

A DTAC-ready build starts with clinical safety alongside product discovery. The clinical safety officer joins early workshops, hazards are logged as features are designed, and the controls that mitigate them become requirements in the backlog. Each release updates the hazard log and safety case, so the documentation always matches the software. That matters, because a mismatch between what a product does and what its DTAC form says can create legal exposure for the supplier.

Data protection shapes the architecture. Hosting is chosen in a UK region, personal data is minimised and encrypted, access follows least privilege, and audit logs record who viewed or changed clinical records. Security is built into the delivery pipeline, with dependency scanning, secure configuration, separate environments, multi-factor authentication for administrators and a penetration test before release. Interoperability is designed around FHIR resources and NHS identity services from the start, and accessibility is tested continuously against WCAG 2.2 AA rather than audited at the end.

Ownership of the evidence matters as much as the evidence itself. Cyber Essentials certificates and penetration tests expire after a year, and each new product version needs an up-to-date form. Suppliers that treat DTAC as part of their release process, rather than a one-off submission, answer buyer questions faster and avoid reassessment delays. Home care suppliers face additional sector rules, set out in our guide to UK home care software requirements.

DTAC and the Innovation Passport

The 2026 update forms part of the government's innovation passport approach, which aims to stop suppliers from proving the same compliance again and again to every NHS organisation they sell to. NHS England is exploring an online repository where a supplier's DTAC form could be shared with several buyers. Until that exists, suppliers should expect each buying organisation to run its own assessment, and should keep a single, current evidence pack that can be shared quickly.

Summary

DTAC is the baseline assessment NHS and social care buyers use before adopting digital health software. Since 6 April 2026 only the updated form should be used. It is shorter and less duplicative, and its scope is aligned with NICE, but it still expects real evidence across clinical safety, data protection, technical security, interoperability, and usability and accessibility. The most reliable way to pass is to build those requirements into the product and the release process from the first sprint.

TopicKey point
What DTAC isNHS England's baseline assessment for software-based digital health technologies
Current formUpdated form in use from 6 April 2026, about 25 per cent fewer questions
Who completes itThe manufacturer completes it; the buying organisation assesses it
Assessed areasClinical safety, data protection, technical security, interoperability, usability and accessibility
Expiring evidenceCyber Essentials and penetration tests within twelve months; form updated per version
Best approachBuild DTAC evidence into discovery, architecture and every release

Frequently Asked Questions

What is NHS DTAC?

DTAC, the Digital Technology Assessment Criteria, is NHS England's baseline assessment framework for software-based digital health technologies. Suppliers complete the DTAC form with supporting evidence, and NHS and social care organisations assess it before buying or deploying the product.

When did the new DTAC form come into use?

NHS England published the refreshed DTAC form and guidance in February 2026. The previous form should not be used from 6 April 2026 onwards.

Is DTAC a certification?

No. DTAC is an assessment framework, not a certificate or badge. Each buying organisation assesses the supplier's completed form, and elements that expire or change with product updates should be reassessed.

What are the five DTAC assessment areas?

The assessed areas are clinical safety, data protection, technical security, interoperability, and usability and accessibility. Company information and the value proposition are collected for context but are not assessed.

Does my product need a clinical safety officer for DTAC?

If your product provides information that influences, supports or manages direct patient care, the clinical safety section applies and you need a named clinical safety officer who is a registered clinician, working to the DCB0129 standard. Since the 2026 update, NHS-provided training for that officer is no longer mandatory.

Can DTAC requirements be built into a new product from the start?

Yes, and that is the most efficient approach. Logging hazards during design, choosing UK hosting, building audit logs and multi-factor authentication, designing integrations around FHIR and NHS identity services, and testing accessibility continuously all reduce the work needed when a buyer requests the form.

Build DTAC-Ready Health Software With Pixbit

Pixbit designs and builds digital health platforms, clinical apps and patient-facing products with DTAC evidence built into the delivery process, including hazard logging alongside design, UK hosting, audit trails, FHIR-based integrations and continuous WCAG 2.2 AA testing. Pixbit prepares the technical evidence your clinical safety officer and information governance lead need, while the assessment itself remains with the buying organisation. A focused patient-facing tool sits at the lower end of the investment range and a multi-role clinical platform with NHS integrations at the higher end. Explore our healthcare software development service or book a discovery session, and Pixbit scopes in a single discovery session.

Nabeel Al Nassir
Author
Nabeel Al Nassir

Digital Marketer

Share on

https://pixbitsolutions.com/blogs/nhs-dtac-digital-health-software-requirements
Have an idea that needs to go mobile? Launch it with us!

Have an idea that needs to go mobile? Launch it with us!

Let's Talk
Contact Us

You May Also Like

Explore insightful articles and tips from our experts on the latest trends in web development and marketing.

Have an idea ?

Let's make it happen

Tell us your business aspirations, and let's craft a custom solution that drives business growth, ensuring satisfaction and exceeding your goals with precision.

Let's Talk